THERMODYNAMICS - THEORY
|
|
|
Many engineering devices operate essentially under the same
conditions for long periods of time. Therefore, these devices can be treated
as steady-flow devices.
Recall,
the energy balance for a control volume is:
|
|
|
|
|
|
Heat Exchangers
|
|
|
Devices that transfer energy between fluids at different
temperatures by heat transfer modes such as conduction, convection, and
radiation are called heat exchangers.
|
|
|
|
Recuperator |
|
The simplest form of a heat exchanger is called a recuperator, in
which a gas or liquid is separated from another gas or liquid by a
wall through which energy passes by conduction.
The conservation of mass principle for a heat exchanger can be expressed
as follows:
Under steady operation, the mass flow rate
of each fluid stream flowing through a heat exchanger remains
constant. |
Hence,
There are several common assumptions that are made in the energy
analysis of heat exchangers |
|
|
|
Heat Transfer of Heat Exchangers
|
|
If one takes the entire heat exchanger as a control volume, =
0. If only one of the fluids is selected as a control volume, heat
will cross this boundary as it flows from one fluid to the other. Hence,
The only work interaction at the boundary of a control volume enclosing
a heat exchanger is flow work and no shaft or electric work is involved.
The change in kinetic energy is insignificant.
The potential energy change is negligible.
|
|
|
|
|
|
Pipe and Duct Flow
|
Pipe Are Used to Transfer Fluid
from one Device to another
|
|
Pipes and ducts are used to transfer fluid from one device
to another. Flow through a pipe or duct can be treated as a steady-flow
process since the start-up and shut-down periods, which are transient process; are excluded.
When flow through pipes or ducts are analyzed, the following points should be considered:
-
If the pipes or ducts are insulated, heat transfer from the pipes or
ducts to the environments is negligible. Under normal operating conditions,
the pipes or ducts are not insulated, hence the heat gained or
lost is large. Sometimes heat transfer is the main purpose of the flow, for example, in heat
exchangers. In this case, heat transfer needs to be accounted for.
If the control volume involves pumps or fans or other work devices,
the work interaction terms should be considered. Otherwise, the work term is zero.
The change in kinetic energy is insignificant, particularly when the pipe or duct has a constant diameter.
The change in potential energy is large when the fluid undergoes a considerable elevation change.
|
|
|
|
|